Product Details:

Place of Origin: china
Brand Name: HAIRF
Certification: CE ROHS ISO CCC ISO
Model Number: MODELS: R161A, R261A,R401A

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: 4999~8000USD
Packaging Details: wooden case
Delivery Time: 25~30 working days
Payment Terms: T/T
Supply Ability: 600 unit/month
Get Best Price Contact Now

Detail Information

Condition: Newly Made Item: Cabinet Air Conditioner,Evaporative Air Cooler,Air Handling Unit,Chiller,precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton
Operating Voltage: 380/400 VAC,230 VAC,48V,220V,115 VAC FREE Service: 1 Year
Product: Refrigeration Equipment Unit,Precision Air Conditioning Cooling Capacity: 15.5~41.6kw
Fan MODEL: AC/EC FAN Power: 220V 1PHASE 50HZ
Airvolumn: 3200~8500 M3/h,level Flow, Back Air Return
High Light:

EC Fan precision air unit

,

Precision Air Conditioner 15.5kw

,

High Airflow In Row Air Conditioner

Product Description

DX 15.5kw Inrow Precision Air Conditioner With EC Fan Evaporator Close Control Unit High Airflow

15.5kw inrow precision air conditioner with EC fan evaporator close control unit airflow

 

Telecom Air Conditioning INROW type space-saving CRAC used in module data center smart control

 

PARAMETERS

Air cooled: 

 

Modelandoor unit) R161A R261A R361A
Main Power Supply 380V 3Ph-50Hz
40DB / 20%RH  
Total cooling Capacity (kW) 15.5 25.5 41.6
Sensible cooling capacity(kW) 15.5 25.5 41 .6
37DB / 24%RH      
Total cooling Capacity (kW) 14.7 24.1 39.9
Sensible cooling capacity(kW) 14.7 24.1 39.9
35DB / 26%RH      
Total cooling Capacity (kW) 14.1 22.9 37.9
Sensible cooling capacity(kW) 14.1 22.9 37.9
32DB / 29%RH      
Total cooling Capacity (kW) 13.2 21.6 36.8
Sensible cooling capacity(kW) 13.2 21.6 36.1
30DB / 34%RH      
Total cooling Capacity (kW) 12.5 20.5 35.3
Sensible cooling capacity(kW) 12.5 20.5 33.6
Displacement(m/ h) 2800 5200 8600
Fan quantity 6 6 3
Electric heater      
Heating capacity kW 3 3 6
Humidifier      
humidify capacity-kg/h 3 3 3
Pipe dimensions      
Liquid pipes mm 12.7 12.7 15.9
sas pipes -mm 19.05 19.05 22.2
Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
Condensing pump dain pipes imer diameter 25 25 25
Width*Depth*Height (mm) 300 × 1080×2000 300 × 1080×2000 600 × 1080×2000
Weight(kg) 115 155 340
Max.working current of condensing unit(A)      
Single cooling 12.2 19.1 31.8
Single cooling+ Humidifer 15.7 21.8 35.9
| Single coling+ Humidifier theaing 16.9 23.5 41.3
Recommended air switch and cables sizes      
Single cooling Air switch (A) 32 32 50
Cables ( mm2) 6 6 10
Single cooling+Humidifier Air switch (A) 32 32 50
Cables ( mm2) 6 6 10
Single cooling+Humidifer+heating Air switch (A) 32 32 63
Cables ( mm2) 6 6 10

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 0In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 1

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 2

Water cooled inrow air conditioner:

 

Modelandoor unit) R161W R261W R361W
Main Power Supply 380V 3Ph-50Hz
40DB / 20%RH  
Total cooling Capacity (kW) 16.7 27.5 42.3
Sensible cooling capacity(kW) 16.7 27.5 42.3
37DB / 24%RH      
Total cooling Capacity (kW) 15.6 25.9 41.2
Sensible cooling capacity(kW) 15.6 25.9 41.2
35DB / 26%RH      
Total cooling Capacity (kW) 15.3 23.8 38.8
Sensible cooling capacity(kW) 15.3 23.8 38.8
32DB / 29%RH      
Total cooling Capacity (kW) 14.3 22.6 37.4
Sensible cooling capacity(kW) 14.3 22.6 36.8
30DB / 34%RH      
Total cooling Capacity (kW) 13.5 21.9 36.7
Sensible cooling capacity(kW) 13.5 21.9 34.7
Displacement(m/ h) 3000 5500 8200
Fan quantity 6 6 3
Electric heater      
Heating capacity kW 3 3 6
Humidifier      
humidify capacity-kg/h 3 3 3
Pipe dimensions      
Liquid pipes mm 12.7 12.7 12.7
sas pipes -mm 19.05 19.05 19.05
Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
Condensing pump dain pipes imer diameter 25 25 25
Width*Depth*Height (mm) 300 x 1080x 2000 300 x 1080x 2000 300 x 1080x 2000
Weight(kg) 120 150 150
Max.working current of condensing unit(A)      
Single cooling 11.8 19 31.1
Single cooling+ Humidifer 15.5 21.5 34.6
| Single coling+ Humidifier theaing 16.7 23.4 40.5
Recommended air switch and cables sizes      
Single cooling 32 32 50
Single cooling+Humidifier 6 6 10
  32 32 50
Single cooling+
Humidifier+heating
6 6 10
  32 32 63
Single cooling+
Humidifier+heating
6 6 10

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 3

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 4In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 5In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 6In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 7In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 8

Packaging:

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 9

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 10

Certification:

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 11

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 12

 

Trade Show:

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 13

 

R&D

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 14

 

HAIRF FACTORY PICTURE:

In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow 15

 

Why Need Precision Air Conditioner

1- IT hardware is very sensitive to changes in temperature or humidity. A temperature/humidity swing can create huge cost lose:

  • Temperature variations can alter the electrical and physical characteristics of electronic chips and other board components, causing faulty operation or failure.
  • High humidity can result in tape and surface deterioration, head crashes, condensation, corrosion, paper handling problems, and gold and silver migration leading to component and board failure.
  • Low humidity greatly increases the possibility of static electric discharges. Such static discharges can corrupt data and damage hardware.

2- Standard comfort air conditioning is usually no dedicated humidity control and the simple controllers cannot maintain the set point tolerance required for temperature, allowing potentially harmful temperature and humidity swings to occur.

 

3- Precision Air Conditioner / Precision Air Conditioning Unit is designed for close temperature and humidity control (±1°C and ±3-5% R.H). It provides high reliability for year-round operation, with the ease of service, system flexibility and redundancy necessary to keep the technology room up and running 24 hours a day.

Want to Know more details about this product
I am interested in In Row 15.5kw Precision Air Conditioner With EC Fan High Airflow could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.