• Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H
  • Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H
  • Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H
  • Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H
  • Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H
Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H

Product Details:

Place of Origin: CN
Brand Name: HAIRF
Certification: CE ROHS ISO CCC
Model Number: R161A, R261A,R401A

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: 1999~8000USD
Packaging Details: wooden case
Delivery Time: 25~35 working days
Payment Terms: T/T
Supply Ability: 500 unit/month
Get Best Price Contact Now

Detail Information

Condition: NewLY CUSTOMIZED NAME: Cabinet Air Conditioner,Evaporative Air Cooler,Air Handling Unit,Chiller,precision Air Conditioning Unit(chilled Water) 3ton 5ton 10ton
VOLTAGE: 220V/1PHASE/60HZ FREE Service: 1 Year
Product Name: Refrigeration Equipment Unit,Precision Air Conditioning Cooling: 15~41.6kw
Fan MODEL: Direct Driven/belt Driven/AC/EC Plug Fan,AC Direct Drive Fan Power: 3N-380V-60Hz
Airvolumn: 3000~50000 M3/h,Downflow/up Air Return
High Light:

Precision Ac Unit Inrow

,

Air Cooled Precision Air Conditioner

,

Precision Ac Unit Split Type

Product Description

Air cooled inrow precision air conditioner 3200m3/h split type PAC for server rooom air cooling

 

Telecom Air Conditioning column space-saving CRAC used in module data center smart control

 

PARAMETERS

 

Modelandoor unit) R161A R261A R361A
Main Power Supply 380V 3Ph-50Hz
40DB / 20%RH  
Total cooling Capacity (kW) 15.5 25.5 41.6
Sensible cooling capacity(kW) 15.5 25.5 41 .6
37DB / 24%RH      
Total cooling Capacity (kW) 14.7 24.1 39.9
Sensible cooling capacity(kW) 14.7 24.1 39.9
35DB / 26%RH      
Total cooling Capacity (kW) 14.1 22.9 37.9
Sensible cooling capacity(kW) 14.1 22.9 37.9
32DB / 29%RH      
Total cooling Capacity (kW) 13.2 21.6 36.8
Sensible cooling capacity(kW) 13.2 21.6 36.1
30DB / 34%RH      
Total cooling Capacity (kW) 12.5 20.5 35.3
Sensible cooling capacity(kW) 12.5 20.5 33.6
Displacement(m/ h) 2800 5200 8600
Fan quantity 6 6 3
Electric heater      
Heating capacity kW 3 3 6
Humidifier      
humidify capacity-kg/h 3 3 3
Pipe dimensions      
Liquid pipes mm 12.7 12.7 15.9
sas pipes -mm 19.05 19.05 22.2
Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
Condensing pump dain pipes imer diameter 25 25 25
Width*Depth*Height (mm) 300 × 1080×2000 300 × 1080×2000 600 × 1080×2000
Weight(kg) 115 155 340
Max.working current of condensing unit(A)      
Single cooling 12.2 19.1 31.8
Single cooling+ Humidifer 15.7 21.8 35.9
| Single coling+ Humidifier theaing 16.9 23.5 41.3
Recommended air switch and cables sizes      
Single cooling Air switch (A) 32 32 50
Cables ( mm2) 6 6 10
Single cooling+Humidifier Air switch (A) 32 32 50
Cables ( mm2) 6 6 10
Single cooling+Humidifer+heating Air switch (A) 32 32 63
Cables ( mm2) 6 6 10

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 0Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 1

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 2

Water cooled inrow air conditioner:

 

Modelandoor unit) R161W R261W R361W
Main Power Supply 380V 3Ph-50Hz
40DB / 20%RH  
Total cooling Capacity (kW) 16.7 27.5 42.3
Sensible cooling capacity(kW) 16.7 27.5 42.3
37DB / 24%RH      
Total cooling Capacity (kW) 15.6 25.9 41.2
Sensible cooling capacity(kW) 15.6 25.9 41.2
35DB / 26%RH      
Total cooling Capacity (kW) 15.3 23.8 38.8
Sensible cooling capacity(kW) 15.3 23.8 38.8
32DB / 29%RH      
Total cooling Capacity (kW) 14.3 22.6 37.4
Sensible cooling capacity(kW) 14.3 22.6 36.8
30DB / 34%RH      
Total cooling Capacity (kW) 13.5 21.9 36.7
Sensible cooling capacity(kW) 13.5 21.9 34.7
Displacement(m/ h) 3000 5500 8200
Fan quantity 6 6 3
Electric heater      
Heating capacity kW 3 3 6
Humidifier      
humidify capacity-kg/h 3 3 3
Pipe dimensions      
Liquid pipes mm 12.7 12.7 12.7
sas pipes -mm 19.05 19.05 19.05
Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
Condensing pump dain pipes imer diameter 25 25 25
Width*Depth*Height (mm) 300 x 1080x 2000 300 x 1080x 2000 300 x 1080x 2000
Weight(kg) 120 150 150
Max.working current of condensing unit(A)      
Single cooling 11.8 19 31.1
Single cooling+ Humidifer 15.5 21.5 34.6
| Single coling+ Humidifier theaing 16.7 23.4 40.5
Recommended air switch and cables sizes      
Single cooling 32 32 50
Single cooling+Humidifier 6 6 10
  32 32 50
Single cooling+
Humidifier+heating
6 6 10
  32 32 63
Single cooling+
Humidifier+heating
6 6 10

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 3

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 4Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 5Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 6Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 7Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 8

Packaging:

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 9

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 10

Certification:

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 11

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 12

 

Basic Information about Hairf precision air conditioning
1. What is Hairf basic information?
Ans: HEFEI HAIRF INTERNATIONAL TRADING CO., LTD Established in 2005, a China Base Air Conditioners manufacturer.

Our mother company is Beijing HAIRF.
Products from our factory:
A. Air Conditioners Power Type
B. Split Air Conditioners outdoor condensing units
C. Split Air Conditioners indoor Units
D. Floor Standing indoor Units
E. Fan Coil Type Indoor Units
F. Industrial or Special Precision Cooling
1. Server Room Precision Cooling
2. Industrial Cabinet Cooling
3. Cultivation Climate Control System
4. Rack Cooler: 2.3~3.0KW
5. Server Room Air Conditioners Smart Management System


 

 

Trade Show:

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 13

 

R&D

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 14

 

HAIRF FACTORY PICTURE:

Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H 15

 

Why Need Precision Air Conditioner

1- IT hardware is very sensitive to changes in temperature or humidity. A temperature/humidity swing can create huge cost lose:

  • Temperature variations can alter the electrical and physical characteristics of electronic chips and other board components, causing faulty operation or failure.
  • High humidity can result in tape and surface deterioration, head crashes, condensation, corrosion, paper handling problems, and gold and silver migration leading to component and board failure.
  • Low humidity greatly increases the possibility of static electric discharges. Such static discharges can corrupt data and damage hardware.

2- Standard comfort air conditioning is usually no dedicated humidity control and the simple controllers cannot maintain the set point tolerance required for temperature, allowing potentially harmful temperature and humidity swings to occur.

 

3- Precision Air Conditioner / Precision Air Conditioning Unit is designed for close temperature and humidity control (±1°C and ±3-5% R.H). It provides high reliability for year-round operation, with the ease of service, system flexibility and redundancy necessary to keep the technology room up and running 24 hours a day.

Want to Know more details about this product
I am interested in Air Cooled Inrow Precision Air Conditioner Split Type For Server Room 3200m3/H could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.