Product Details:

Place of Origin: CN
Brand Name: HAIRF
Certification: CE 3CE RoHS
Model Number: R161A

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: $2699-8519/set
Packaging Details: wooden case
Delivery Time: 35-45days
Payment Terms: T/T
Supply Ability: 500set/month
Get Best Price Contact Now

Detail Information

Waranty: One Year Color: Black
Flow: 2800m³ Selling Point: Save Space&large Cooling Capacity
Cooling Capacity: 15.5kw Cooling Type: Air Cooled Type
Air Flow: Level Package: Wooden Pack
Size: 600*1100*2000mm/300*1100*2000mm
High Light:

Black Precision Air Conditioning Equipment

,

High Cooling Strength Precision Ac Unit

,

IT Room Precision Ac Unit

Product Description

High cooling strength IT room precision air conditioner in row crac EC fan high configuration

 

Modelandoor unit) R161A R261A R361A
Main Power Supply 380V 3Ph-50Hz
40DB / 20%RH  
Total cooling Capacity (kW) 15.5 25.5 41.6
Sensible cooling capacity(kW) 15.5 25.5 41 .6
37DB / 24%RH      
Total cooling Capacity (kW) 14.7 24.1 39.9
Sensible cooling capacity(kW) 14.7 24.1 39.9
35DB / 26%RH      
Total cooling Capacity (kW) 14.1 22.9 37.9
Sensible cooling capacity(kW) 14.1 22.9 37.9
32DB / 29%RH      
Total cooling Capacity (kW) 13.2 21.6 36.8
Sensible cooling capacity(kW) 13.2 21.6 36.1
30DB / 34%RH      
Total cooling Capacity (kW) 12.5 20.5 35.3
Sensible cooling capacity(kW) 12.5 20.5 33.6
Displacement(m/ h) 2800 5200 8600
Fan quantity 6 6 3
Electric heater      
Heating capacity kW 3 3 6
Humidifier      
humidify capacity-kg/h 3 3 3
Pipe dimensions      
Liquid pipes mm 12.7 12.7 15.9
sas pipes -mm 19.05 19.05 22.2
Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
Condensing pump dain pipes imer diameter 25 25 25
Width*Depth*Height (mm) 300 × 1080×2000 300 × 1080×2000 600 × 1080×2000
Weight(kg) 115 155 340
Max.working current of condensing unit(A)      
Single cooling 12.2 19.1 31.8
Single cooling+ Humidifer 15.7 21.8 35.9
| Single coling+ Humidifier theaing 16.9 23.5 41.3
Recommended air switch and cables sizes      
Single cooling Air switch (A) 32 32 50
Cables ( mm2) 6 6 10
Single cooling+Humidifier Air switch (A) 32 32 50
Cables ( mm2) 6 6 10
Single cooling+Humidifer+heating Air switch (A) 32 32 63
Cables ( mm2) 6 6 10

 

High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan 0

Modelandoor unit) R161W R261W R361W
Main Power Supply 380V 3Ph-50Hz
40DB / 20%RH  
Total cooling Capacity (kW) 16.7 27.5 42.3
Sensible cooling capacity(kW) 16.7 27.5 42.3
37DB / 24%RH      
Total cooling Capacity (kW) 15.6 25.9 41.2
Sensible cooling capacity(kW) 15.6 25.9 41.2
35DB / 26%RH      
Total cooling Capacity (kW) 15.3 23.8 38.8
Sensible cooling capacity(kW) 15.3 23.8 38.8
32DB / 29%RH      
Total cooling Capacity (kW) 14.3 22.6 37.4
Sensible cooling capacity(kW) 14.3 22.6 36.8
30DB / 34%RH      
Total cooling Capacity (kW) 13.5 21.9 36.7
Sensible cooling capacity(kW) 13.5 21.9 34.7
Displacement(m/ h) 3000 5500 8200
Fan quantity 6 6 3
Electric heater      
Heating capacity kW 3 3 6
Humidifier      
humidify capacity-kg/h 3 3 3
Pipe dimensions      
Liquid pipes mm 12.7 12.7 12.7
sas pipes -mm 19.05 19.05 19.05
Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
Condensing pump dain pipes imer diameter 25 25 25
Width*Depth*Height (mm) 300 x 1080x 2000 300 x 1080x 2000 300 x 1080x 2000
Weight(kg) 120 150 150
Max.working current of condensing unit(A)      
Single cooling 11.8 19 31.1
Single cooling+ Humidifer 15.5 21.5 34.6
| Single coling+ Humidifier theaing 16.7 23.4 40.5
Recommended air switch and cables sizes      
Single cooling 32 32 50
Single cooling+Humidifier 6 6 10
  32 32 50
Single cooling+
Humidifier+heating
6 6 10
  32 32 63
Single cooling+
Humidifier+heating
6 6 10

High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan 1

High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan 2High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan 3High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan 4High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan 5High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan 6

High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan 7

 

Main Features of HAIRF Precise Air Conditioning

  • Highly sensible cooling system.
  • Intelligent dehumidification, without reduction in air flow.
  • Fan is provided with speed control so that the cooling performance and the noise level of theunit can be tailored to application.
  • Lower power consumption.
  • Intelligent supervision and reliability through monitoring of all components with precise and clear display of any malfunction or abnormal conditions.
  • Accessories can be incorporated
  • High fire tolerance.
  • High pressure strength.

 

 

Why Us?

 

HeFei HAIRF international trading., ltd provides solutions for any type of environment friendly precise air

conditioning need. Being precision air conditioner professional manufaturer, we have more than 30years

R&D and manufature experience. We can provide competitive discount on our products and are able to

sell these at lower than market rates and also provide much better after-sales sales service.

Want to Know more details about this product
I am interested in High Cooling Strength Precision Ac Unit For IT Room In Row Crac EC Fan could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.