HAIRF 10kva Three Phase Tower Type UPS Uninterruptible Power Supply
Product Details:
Place of Origin: | China |
Brand Name: | HAIRF |
Certification: | CE, ROHS, CCC |
Model Number: | X2-3110L |
Payment & Shipping Terms:
Minimum Order Quantity: | 1set |
---|---|
Price: | USD550 - USD620 |
Packaging Details: | carton box & wooden pallet |
Delivery Time: | 7days |
Payment Terms: | T/T, Western Union |
Supply Ability: | 10000sets/month |
Detail Information |
|||
Model No.: | X2-3110L | Color: | Black |
---|---|---|---|
Installation: | Tower Type | Application: | Server Room |
Package: | Wooden Case | Brand: | HAIRF |
Capacity: | 10kva | Voltage: | Customized Acceptable |
High Light: | HAIRF Tower Type UPS,HAIRF UPS Uninterruptible Power Supply,10kva UPS Uninterruptible Power Supply |
Product Description
Three phase input single phase output tower type ups with back up battery
Hairf X2 series All intelligent high frenquency pure online UPS, which are generally used on places required high quality electricity,such as hospital equipments,corporations,IT loading equipments,industrial computer terminals. As UPS inverter circuit always in a state of work,the stored energy of UPS can be inverted and output alternating current without switching.X2 series UPS support different types of operation systems,apply to TCP/IP local LAN and support the networking monitoring of UPS.
Product feature:
Support LBS synchronic control;
Intelligent Fan speed regulation function;
Support bypass maintenance(three phase input single phase output);
LCD display function,user friendly display interface;
Three-stage extensible charging design to ensure a more remarkable perfomnce of the batteries;
Support parallel opretion of more than 3 machines with shared battery packs;
Support DC cold starting;without utility, the load can keep operating with the power offered by batteries;
Powerful charging function is convinient to extense the capacity of standby batteries.Intelligent charging mode even extending battery life to cut down expenditures;
Support automatic restart function: when utility goes normal after UPS is shutdown under battery mode,UPS can automatic restart;
Good technical indicators: the approximate 1 input power factor,largely decreased the pollution to utility grid and improved the use ratio of grid,so X2 series UPS are real eco-type power;
Design:
Advanced DSP digital control technology, guarantee high UPS performance, products stable and quality reliable;
Zero switching time:when the city electricity is abornomal,UPS will turn to battery mode with zero time,which can effectively ensure the safety and reliability of the instruments;
Green &Environment:Meet the State Administration of electronic information products’ pollution control,will cause no harm to human and envirnment under normal usage;
Frequency adaptive system: In order to meet different power system requirements, it can be set to fixed or automatic idetification to fit for 50Hz/60Hz;
Input power factor correction function enable the factor to be over 0.99 to avoid grid environment pollution,so as to save energy and decrease cost;
Wide input voltage and frequency range:Even in places where electricity environment is very bad, it can also keep stable work under utility supply mode,which decrease the number of battery discharge and prolong the service life of batteries.
Technical data
Model | X2-1101(L) | X2-1102(L) | X2-1103(L) | X2-1106(L) | X2-1110(L) | |
Capadity | 1KVA /0.8KW | 2KVA /1.6KW | 3KVA / 2.4KW | 6KVA / 4.8KW | 10KVA / 8KW | |
Input | ||||||
Connection Mode | Single phase earthing | |||||
Input Voltage | 200 / 208 / 220 / 230 /240VAC | |||||
Voltage Range | 110-300VAC | |||||
Frequency | 40-70Hz | |||||
Power factor | ≥0.99 | |||||
Output | ||||||
Output Voltage | 200 / 208 / 220 / 230 /240VAC | |||||
Voltage regulation | ±1% | |||||
Frequency | Synchronous correction range | 46-54Hz / 56-64Hz | ||||
Battery Model | 50Hz ±0.1Hz / 60Hz ±0.1Hz | |||||
Distortion(THDU) | ≤3% | |||||
Peak Cofficient | ≥3:1 | |||||
Overload Capacity | 110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min. | |||||
Time switching | Electric City/Battery | 0ms | ||||
Inverter/Bypass | <4ms (standard environment) | 0ms | ||||
Battery | ||||||
Standard Machine | Battery Cells | 2 | 4 | 6 | / | |
Charging Current | 1.0A (MAX) | 2.0A (MAX) | ||||
Battery Model | 12V / 9Ah | |||||
Long Lasting | Battery Cells | 3 | 6 | 8 | 16(16-20 optional) | |
Charging Current | 1A/2A/4A/6A settable | |||||
Battery Model | Depends on the applicant | |||||
Control Management | ||||||
City Electricity Model | ≥91% | ≥93% | ||||
Battery Model | ≥91% | ≥93% | ||||
Display Interface | ||||||
LCD/LED | Loading Size, Battery Capacity, City Electricity Mode, Battery Mode, Bypass Mode, Fault Indication | |||||
Control Management | ||||||
Intelligent RS-232/USB | Support Windows 2000/2003/XP/Vista/2008,Windows 7/8,Linux,Unix and MAC | |||||
Option SNMP | Support SNMP Internet Management | |||||
Environment | ||||||
Temperature | 0-40℃ | |||||
Relative Humidity | 0-95%(Non Condensing) | |||||
Noise | < 50dB @1m | < 55dB @1m | < 58dB @1m | |||
Physical Character | ||||||
Standard | Size: Width*Depth *Height(mm) | 145*282*220 | 145*397*220 | 190*421*318 | 190*369*688 | 190*442*688 |
Machine | Net Weight(kg) | 11 | 18 | 29 | 62 | 67 |
L o n g Lasting | Size:Width*Depth *Height(mm) | 145*282*220 | 145*397*220 | 190*369*318 | 190*442*318 | |
Net Weight(kg) | 6 | 8 | 9 | 13 | 17 |