Product Details:

Place of Origin: CN
Brand Name: HAIRF
Certification: CE 3CE RoHS
Model Number: R161A

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: $2699-8519/set
Packaging Details: wooden case
Delivery Time: 35-45days
Payment Terms: T/T
Supply Ability: 500set/month
Get Best Price Contact Now

Detail Information

Waranty: One Year Color: Black
Flow: 2800m³ Selling Point: Save Space&large Cooling Capacity
Cooling Capacity: 15.5kw Cooling Type: Air Cooled Type
Air Flow: Level Package: Wooden Pack
Size: 600*1100*2000mm/300*1100*2000mm
High Light:

15.5kw Server Room Air Conditioner

,

Server Room Air Conditioner

,

15.5kw crac unit ac

Product Description

Server room air conditioner cooling capacity 30kw inrow AC with main power supply

 

 

2000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 0

Modelandoor unit) R161A R261A R361A
Main Power Supply 380V 3Ph-50Hz
40DB / 20%RH  
Total cooling Capacity (kW) 15.5 25.5 41.6
Sensible cooling capacity(kW) 15.5 25.5 41 .6
37DB / 24%RH      
Total cooling Capacity (kW) 14.7 24.1 39.9
Sensible cooling capacity(kW) 14.7 24.1 39.9
35DB / 26%RH      
Total cooling Capacity (kW) 14.1 22.9 37.9
Sensible cooling capacity(kW) 14.1 22.9 37.9
32DB / 29%RH      
Total cooling Capacity (kW) 13.2 21.6 36.8
Sensible cooling capacity(kW) 13.2 21.6 36.1
30DB / 34%RH      
Total cooling Capacity (kW) 12.5 20.5 35.3
Sensible cooling capacity(kW) 12.5 20.5 33.6
Displacement(m/ h) 2800 5200 8600
Fan quantity 6 6 3
Electric heater      
Heating capacity kW 3 3 6
Humidifier      
humidify capacity-kg/h 3 3 3
Pipe dimensions      
Liquid pipes mm 12.7 12.7 15.9
sas pipes -mm 19.05 19.05 22.2
Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
Condensing pump dain pipes imer diameter 25 25 25
Width*Depth*Height (mm) 300 × 1080×2000 300 × 1080×2000 600 × 1080×2000
Weight(kg) 115 155 340
Max.working current of condensing unit(A)      
Single cooling 12.2 19.1 31.8
Single cooling+ Humidifer 15.7 21.8 35.9
| Single coling+ Humidifier theaing 16.9 23.5 41.3
Recommended air switch and cables sizes      
Single cooling Air switch (A) 32 32 50
Cables ( mm2) 6 6 10
Single cooling+Humidifier Air switch (A) 32 32 50
Cables ( mm2) 6 6 10
Single cooling+Humidifer+heating Air switch (A) 32 32 63
Cables ( mm2) 6 6 10

 

2000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 1

Modelandoor unit) R161W R261W R361W
Main Power Supply 380V 3Ph-50Hz
40DB / 20%RH  
Total cooling Capacity (kW) 16.7 27.5 42.3
Sensible cooling capacity(kW) 16.7 27.5 42.3
37DB / 24%RH      
Total cooling Capacity (kW) 15.6 25.9 41.2
Sensible cooling capacity(kW) 15.6 25.9 41.2
35DB / 26%RH      
Total cooling Capacity (kW) 15.3 23.8 38.8
Sensible cooling capacity(kW) 15.3 23.8 38.8
32DB / 29%RH      
Total cooling Capacity (kW) 14.3 22.6 37.4
Sensible cooling capacity(kW) 14.3 22.6 36.8
30DB / 34%RH      
Total cooling Capacity (kW) 13.5 21.9 36.7
Sensible cooling capacity(kW) 13.5 21.9 34.7
Displacement(m/ h) 3000 5500 8200
Fan quantity 6 6 3
Electric heater      
Heating capacity kW 3 3 6
Humidifier      
humidify capacity-kg/h 3 3 3
Pipe dimensions      
Liquid pipes mm 12.7 12.7 12.7
sas pipes -mm 19.05 19.05 19.05
Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
Condensing pump dain pipes imer diameter 25 25 25
Width*Depth*Height (mm) 300 x 1080x 2000 300 x 1080x 2000 300 x 1080x 2000
Weight(kg) 120 150 150
Max.working current of condensing unit(A)      
Single cooling 11.8 19 31.1
Single cooling+ Humidifer 15.5 21.5 34.6
| Single coling+ Humidifier theaing 16.7 23.4 40.5
Recommended air switch and cables sizes      
Single cooling 32 32 50
Single cooling+Humidifier 6 6 10
  32 32 50
Single cooling+
Humidifier+heating
6 6 10
  32 32 63
Single cooling+
Humidifier+heating
6 6 10

2000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 2

2000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 32000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 42000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 52000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 62000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 72000mm Height 30kw Server Room Air Conditioner Crac Unit Ac 8