    Product Details:

    Place of Origin: CN
    Brand Name: HAIRF
    Certification: CE 3CE RoHS
    Model Number: R161A

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: $2699-8519/set
    Packaging Details: wooden case
    Delivery Time: 35-45days
    Payment Terms: T/T
    Supply Ability: 500set/month
    Get Best Price Contact Now

    Detail Information

    Waranty: One Year Color: Black
    Flow: 2800m³ Selling Point: Save Space&large Cooling Capacity
    Cooling Capacity: 15.5kw Cooling Type: Air Cooled Type
    Air Flow: Level Package: Wooden Pack
    Size: 600*1100*2000mm/300*1100*2000mm
    High Light:

    3CE RoHS in row cooling system

    ,

    30kw in row cooling system

    ,

    3CE RoHS portable ac unit for server room

    Product Description

    Server room air conditioner cooling capacity 30kw inrow AC with main power supply

     

    3CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 0

    Modelandoor unit) R161A R261A R361A
    Main Power Supply 380V 3Ph-50Hz
    40DB / 20%RH  
    Total cooling Capacity (kW) 15.5 25.5 41.6
    Sensible cooling capacity(kW) 15.5 25.5 41 .6
    37DB / 24%RH      
    Total cooling Capacity (kW) 14.7 24.1 39.9
    Sensible cooling capacity(kW) 14.7 24.1 39.9
    35DB / 26%RH      
    Total cooling Capacity (kW) 14.1 22.9 37.9
    Sensible cooling capacity(kW) 14.1 22.9 37.9
    32DB / 29%RH      
    Total cooling Capacity (kW) 13.2 21.6 36.8
    Sensible cooling capacity(kW) 13.2 21.6 36.1
    30DB / 34%RH      
    Total cooling Capacity (kW) 12.5 20.5 35.3
    Sensible cooling capacity(kW) 12.5 20.5 33.6
    Displacement(m/ h) 2800 5200 8600
    Fan quantity 6 6 3
    Electric heater      
    Heating capacity kW 3 3 6
    Humidifier      
    humidify capacity-kg/h 3 3 3
    Pipe dimensions      
    Liquid pipes mm 12.7 12.7 15.9
    sas pipes -mm 19.05 19.05 22.2
    Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
    Condensing pump dain pipes imer diameter 25 25 25
    Width*Depth*Height (mm) 300 × 1080×2000 300 × 1080×2000 600 × 1080×2000
    Weight(kg) 115 155 340
    Max.working current of condensing unit(A)      
    Single cooling 12.2 19.1 31.8
    Single cooling+ Humidifer 15.7 21.8 35.9
    | Single coling+ Humidifier theaing 16.9 23.5 41.3
    Recommended air switch and cables sizes      
    Single cooling Air switch (A) 32 32 50
    Cables ( mm2) 6 6 10
    Single cooling+Humidifier Air switch (A) 32 32 50
    Cables ( mm2) 6 6 10
    Single cooling+Humidifer+heating Air switch (A) 32 32 63
    Cables ( mm2) 6 6 10

     

    3CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 1

    Modelandoor unit) R161W R261W R361W
    Main Power Supply 380V 3Ph-50Hz
    40DB / 20%RH  
    Total cooling Capacity (kW) 16.7 27.5 42.3
    Sensible cooling capacity(kW) 16.7 27.5 42.3
    37DB / 24%RH      
    Total cooling Capacity (kW) 15.6 25.9 41.2
    Sensible cooling capacity(kW) 15.6 25.9 41.2
    35DB / 26%RH      
    Total cooling Capacity (kW) 15.3 23.8 38.8
    Sensible cooling capacity(kW) 15.3 23.8 38.8
    32DB / 29%RH      
    Total cooling Capacity (kW) 14.3 22.6 37.4
    Sensible cooling capacity(kW) 14.3 22.6 36.8
    30DB / 34%RH      
    Total cooling Capacity (kW) 13.5 21.9 36.7
    Sensible cooling capacity(kW) 13.5 21.9 34.7
    Displacement(m/ h) 3000 5500 8200
    Fan quantity 6 6 3
    Electric heater      
    Heating capacity kW 3 3 6
    Humidifier      
    humidify capacity-kg/h 3 3 3
    Pipe dimensions      
    Liquid pipes mm 12.7 12.7 12.7
    sas pipes -mm 19.05 19.05 19.05
    Hunidifier inlet pipes(mother srew) G3/4" G3/4" G3/4"
    Condensing pump dain pipes imer diameter 25 25 25
    Width*Depth*Height (mm) 300 x 1080x 2000 300 x 1080x 2000 300 x 1080x 2000
    Weight(kg) 120 150 150
    Max.working current of condensing unit(A)      
    Single cooling 11.8 19 31.1
    Single cooling+ Humidifer 15.5 21.5 34.6
    | Single coling+ Humidifier theaing 16.7 23.4 40.5
    Recommended air switch and cables sizes      
    Single cooling 32 32 50
    Single cooling+Humidifier 6 6 10
      32 32 50
    Single cooling+
    Humidifier+heating
    6 6 10
      32 32 63
    Single cooling+
    Humidifier+heating
    6 6 10

    3CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 2

    3CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 33CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 43CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 53CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 63CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 73CE RoHS 30kw Portable Ac In Row Cooling System For Server Room 8